欧美自拍另类欧美宗合图片区,国产视频一区二区三区四区,日本一区二区三区四区视频,婬片一区AAA毛片一区二区

您好,歡迎您來(lái)到格朗瑞生物科技公司網(wǎng)站!
[登錄](méi)
[注冊]
  • Content

nanoandmore/Q-AR5/Q-AR5-10/Box of 10 AFM Probes

其他分子產(chǎn)品
nanoandmore/Q-AR5/Q-AR5-10/Box of 10 AFM Probes


商品編號


Q-AR5-10



品牌


NanoAndMore



公司


nanoandmore



公司分類(lèi)


Premounted AFM Probes



Coating:

Reflex Aluminum


Tip shape:

High-Aspect-Ratio


Size

Box of 10 AFM Probes

商品信息

Cantilever:
F: 190 kHz
C: 48 N/m
L: 225 ?m
Applications:
Premounted AFM Probes
Description:

NanoWorld Pointprobe? NCL probes are designed for non-contact or tapping?? mode imaging and offer an alternative to our high frequency non-contact type NCH. The NCL type is recommended if the feedback loop of the microscope does not accept high frequencies or if the detection system needs a minimum cantilever length (> 125 ?m). This probe combines high operation st
ABI
lity with outstanding sensitivity. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced.

All SPM and AFM probes of the Pointprobe? series are made from monolithic silicon which is highly doped to dissipate static charge. They are chemically inert and offer a high mechanical Q-factor for high sensitivity. The tip is shaped like a polygon based pyramid.
For measurements on samples with sidewall angles approaching 90° we offer specially tailored tips showing a high aspect ratio portion with near-vertical sidewalls.
These probes offer unique features:


length of the high aspect ratio portion of the tip > 2 ?m

typical aspect ratio of this portion in the order of 7:1 (when viewed from side as well as along cantilever axis)

half cone angle of the high aspect ratio portion typically < 5°

excellent tip r
ADI
us of curvature ? ?


Premounted AFM probe on a Quesant T-plate for Quesant AFM systems. Based on a NanoWorld
NW-AR5-NCLR
AFM probe.

Aluminum Reflex Coating

The aluminum reflex coating consists of a 30 nm thick aluminum layer deposited on the detector side of the cantilever which enhances the reflectance of the laser beam by a factor of 2.5. Fur
Thermo
re it prevents light from interfering within the cantilever.



AFM Tip:


shape:

High-Aspect-Ratio



height:

10 - 15 ?m



r
ADI
us:

< 10="">


AFM Cantilever:


shape:
Beam


length:
225 ?m
(220 - 230 ?m)*



width:
38 ?m
(33 - 43 ?m)*



thickness:
7 ?m
(6.5 - 7.5 ?m)*



force constant:
48 N/m
(31 - 71 N/m)*



resonance frequency:
190 kHz
(160 - 210 kHz)*




* typical range


上一篇 GenWay/Chicken IgG (Fc) Antibody (Alk Phos)/GWB-Q00033/0.5 mg  下一篇 immunoreagents/Troponin Complex//P184-4

產(chǎn)品貨號:14465.6

14465.6 ¥
11至15個(gè)工作日送達
望都县| 勐海县| 高雄市| 蓝田县| 廊坊市| 介休市| 吐鲁番市| 南平市| 义乌市| 阿坝县| 珲春市| 仪征市| 瑞安市| 黄平县| 嘉善县| 平罗县| 成都市| 航空| 弥渡县| 双牌县| 涿州市| 富锦市| 宣城市| 贵德县| 聊城市| 达日县| 淮北市| 大兴区| 高要市| 精河县| 城步| 高州市| 博客| 武山县| 买车| 临城县| 湖北省| 锦屏县| 民和| 鄂托克前旗| 银川市|