SBI/Exo-Check Exosome Antibody Array/EXORAY-8/8 Arrays
基因編輯
商品編號
EXORAY-8
品牌
SBI
公司
System Biosciences(SBI)
公司分類(lèi)
exosome detection
商品信息
.img-style{heigth:450px;width:450px;}
Overview:
Streamline your exosome detection with Exo-Check Arrays
For the most efficient detection of exosomes, turn to our semi-quantitative Exo-Check Exosome Antibody Arrays. Each array has 12 pre-printed spots and features 8 antibodies for known exosome
Marker
s (CD63, CD81, ALIX, FLOT1, ICAM1, EpCam, ANXA5 and TSG101), a GM130 cis-Golgi
Marker
to monitor any cellular contamination in your exosome isolations, a positive control spot derived from human serum exosomes, and a blank spot as a background control. The kits come complete with a secondary detection mixture conjugated to HRP.
Efficient—includes eight antibodies for known exosome
Marker
s
Flex
IBL
e—compat
IBL
e with most exosome isolation methods, include the ExoQuick
?
family of reagents and ultracentrifugation
Well-designed—includes a control for cellular contamination, a background control (blank spot), and a positive control derived from human serum exosomes
Semi-quantitative—can be used to evaluate relative abundance of certain exosome
Marker
s from a given set of samples
A guide to our Exo-Check Exosome Array antibodies
?
1
2
3
4
5
6
A
Positive control
GM130
FLOT-1
ICAM
ALIX
CD81
B
CD63
EpCam
ANXA5
TSG101
Blank
Positive control
Spot position*
ID
Notes
Link to ExoCarta entry for the human protein
A1
Positive control
Positive control for HRP detection (derived from human serum exosomes)
NA
A2
GM130
Cis-golgi matrix protein—control for cellular contamination in exosome preparation
NA
A3
FLOT1
Flotillin-1
ExoCarta_10211
A4
ICAM1
Intercellular adhesion molecule 1
ExoCarta_3383
A5
ALIX
Programmed cell death 6 interacting protein (PDCD6IP)
ExoCarta_10015
A6
CD81
Tetraspanin
ExoCarta_93185
B1
CD63
Tetraspanin
ExoCarta_967
B2
EpCam
Epithelial cell adhesion molecule; often found in cancer-derived exosomes
ExoCarta_4072
B3
ANXA5
Annexin A5
ExoCarta_308
B4
TSG101
Tumor susceptibility gene 101
ExoCarta_7251
B5
Blank
Background control
NA
B6
Positive control
Positive control for HRP detection (derived from human serum exosomes)
NA
*To correctly orient the array, place the notched corner in the upper left-hand position
Supporting Data:
Streamlined, semi-quantitative exosome detection
Sample data showing exosome detection with an Exo-Check Exosome Antibody Array.
The array was exposed to 300 ?g of exosome proteins isolated from human HT1080 lung sarcoma cell line media using ExoQuick-TC
?
. The positive control spots should provide strong signals to indicate that all of the detection reagents are working properly. The various exosome antibody spots will provide varying levels of signal, depending upon the source of the isolated exosomes. The blank spot serves as a background control and should not have any signal. The GM130 control will only show signal above background if there is cellular contamination in your exosome preparations. Note that the notched corner of the blot is in the upper left-hand position.
產(chǎn)品貨號:8983.2